Online Partial Discharge Analyzer (New 2026 Version)
High accuracy and sensitivity with ultra-low noise
Supports all major PRPD, TW, and PSA patterns
TESLA PD software with enhanced features
Real-time signal analysis during data acquisition
100 MSPS sampling rate with 10- to 12-bit resolution
2 nC calibrator
Lightweight and portable
Displays the number of detected discharge events
Dedicated software for test reporting
Intelligent signal detection algorithm
Supports all Partial Discharge Phase-Resolved Patterns (PRPD)
250 MS/s display sampling rate and 10 MS/s data storage rate
Lightweight and portable
Displays the number of detected discharge events
Dedicated software for test reporting
Intelligent signal detection algorithm
Supports all Partial Discharge Phase-Resolved Patterns (PRPD)
250 MS/s display sampling rate and 10 MS/s data storage rate
Offline Partial Discharge Analyzer
Partial Discharge Coupling Capacitor
Rated voltage from 6 kV to 20 kV
Capacitance from 80 pF to 1000 pF
High electrical and insulation strength with enhanced safety
Approved by Niroo Research Institute and Tavanir Thermal Power Plants Holding
Compliant with IEEE 1434 and IEC 60034-2 standards
Suitable for testing high-voltage cables, motors, and generators
Designed for accurate online and offline partial discharge testing
Capacitance from 80 pF to 1000 pF
High electrical and insulation strength with enhanced safety
Approved by Niroo Research Institute and Tavanir Thermal Power Plants Holding
Compliant with IEEE 1434 and IEC 60034-2 standards
Suitable for testing high-voltage cables, motors, and generators
Designed for accurate online and offline partial discharge testing
High gain and low noise
High fault localization accuracy
128 GB storage capacity
On-site PDF test report generation
FFT and DFT analysis functions for fault type identification
Ultrasonic Partial Discharge Detection and Localization Device
10 MSPS sampling rate
Pulse frequency from 40 Hz to 200 Hz
Rotor winding and turn-to-turn fault detection
Simulation of various rotor fault conditions
Ground fault detection and fault location
Exportable reports in XLS, PDF, and REC formats
Rotor Winding Continuity Tester
Electrical Machines
Partial discharge localization at specific points Winding resistance and insulation resistance testing Rotor and stator borescope inspection Partial discharge measurement and analysis Tan Delta and capacitance testing Insulation withstand voltage testing (Hipot) Rotor Shorted Turns and Rotor-to-Ground testing (RSO) Ultrasonic partial discharge detection and localization
Partial discharge localization at specific points
Winding resistance and insulation resistance testing
Rotor and stator borescope inspection
Partial discharge measurement and analysis
Tan Delta and capacitance testing
Insulation withstand voltage testing (Hipot)
Rotor Shorted Turns and Rotor-to-Ground testing (RSO)
Ultrasonic partial discharge detection and localization
High-Voltage Cables
Tan Delta testing Insulation withstand voltage testing (Hipot) Insulation resistance testing of high-voltage cables Ultrasonic partial discharge detection and localization Partial discharge measurement and analysis of cables and cable terminations
Tan Delta testing
Insulation withstand voltage testing (Hipot)
Insulation resistance testing of high-voltage cables
Ultrasonic partial discharge detection and localization
Partial discharge measurement and analysis of cables and cable terminations
Transmission and Distribution Lines
Partial discharge detection and localization on insulators Insulation condition monitoring of overhead distribution lines
Partial discharge detection and localization on insulators
Insulation condition monitoring of overhead distribution lines
Transformers
Transformer turns ratio testing Frequency Domain Spectroscopy (FDS) moisture analysis Frequency Response Analysis (FRA) testing Tan Delta and capacitance testing Insulation withstand voltage testing (Hipot) Partial discharge localization in bushings Partial discharge measurement and analysis
Transformer turns ratio testing
Frequency Domain Spectroscopy (FDS) moisture analysis
Frequency Response Analysis (FRA) testing
Tan Delta and capacitance testing
Insulation withstand voltage testing (Hipot)
Partial discharge localization in bushings
Partial discharge measurement and analysis
Refineries and Petrochemical Plants
Gas leak detection and localization Leak inspection of valves, drums, and boilers Detection and localization of air ingress in vacuum tanks
Gas leak detection and localization
Leak inspection of valves, drums, and boilers
Detection and localization of air ingress in vacuum tanks
?Why Choose Us
- Knowledge-based company supported by the Science and Technology Park
- Approved by Niroo Research Institute, Thermal Power Plants Holding, and Tavanir
- The only manufacturer of Partial Discharge Coupling Capacitors (TESLA CC) in West Asia
- The only manufacturer of Rotor Shorted Turns (RSO) Testers for power plant generators
- Experience of more than 300 generator tests above 100 MVA in power plants in Iran and abroad
- More than 30 research papers published by our experts and specialists, exclusively in the field of Partial Discharge
- Proudly carrying out all stages of product manufacturing—including design, manufacturing, assembly, and calibration—by our in-house specialists